CTP-F 400-750E3 - HIGH PRESSURE - BREATHING-AIR COMPRESSOR - TIT
CTP-F 400-750E3 - HIGH PRESSURE - BREATHING-AIR COMPRESSOR
CTP-F 400-750E3 - HIGH PRESSURE - BREATHING-AIR COMPRESSOR

compressor and motor mounted on frame with shock absorbers. Frame, manufactured in light weight construction, is designed for easy change of power sources.

micronic type intake filter

Lubrication by oil pump

Intercooler after each stage

aftercooler

final mechanical separator for the removal of oil-/ water condensate

optical oil level control on compressor block

final safety valve 225 bar, 330 bar, 350 bar or 420bar

back pressure/ non return valve

thermal circuit breaker

Automatic star-delta switch

3 m connection cable with EEC connector

hour meter

PURIFICATION SYSTEM F 2400

COMP TRADE long-life transparent filter cartridge with saturatiuon indicator processing in 3 stages (drying, neutralisation, micro filtering)

air quality DIN 3188 / EN 12021 : 2014

filling : MS-AC-MS supplying air quality according to DIN 3188 / EN 12021 : 2014

Regenerable air volume 1200 m³ by 20° ambient temperature.

FILLING RAMP WITH 4 × 300 OR 4 × 200 BAR DIRECT CONNECTION

4 level filling valves with integrated vent G5/8" acc DIN 477

pressure gauge for filling pressure

AUTO-STOP

ON/Off switch, main switch and auto stop when reaching final filling pressure

pressure switch with cut-off when the final pressure is reached

AUTOMATIC DRAINAGE SYSTEM

drains all separators between the individual stages and also the final separator during compressor Operation

unloaded start integrated (automatically draining at every shut-down of the unit)

condensate collecting tank, content approx. 5 litres

sound absorber

timer for autodrain system to adjust the most economical drain-intervals

COMPTROL 1

for oil level control with auto stop and reset button when reaching minimum oil level in the compressor block / oil level indicator. The oil level indicator is situated on front of the compressor-frame for additional easy optical control.

CABINET TEMPERATURE

Cooling Temperature Control

Switching off the compressor when the maximum permissible temperature is exceeded